Hargassner air-to-water heat pump

Airflow-M 5-20 kW COMFORT II

Compact DHW tank with two heating circuits. Energy label: A++ / A+++.

Power range
5-20 kW
DHW tank
250 / 310 l
Outdoor operating temperature
down to −25 °C
Max flow temperature
up to 65 °C
Energy class
A++ / A+++
Airflow-M COMFORT II: outdoor unit and indoor module

The COMFORT II module with DHW tank and two heating circuits

The COMFORT II indoor module provides central control of the entire installation and integrates the DHW tank, one direct and one mixed heating circuit. Depending on the size of the outdoor unit, the tank holds 250 l or 310 l.

  • Built-in 250 / 310 l DHW tank
  • Quick installation, small footprint
  • One direct and one mixed heating circuit, factory-integrated
  • 7″ large colour touchscreen

Place in the Airflow-M range

  1. BASIC
  2. STYLE
  3. COMFORT
  4. COMFORT II

Hydraulic components included in addition to STYLE equipment

3-way changeover valve, 250 / 310 litre DHW tank, storage protection anode, one direct and one mixed heating circuit.

Features shared by all Airflow-M variants

The monoblock outdoor unit and the technology are the same in all four variants. Only the equipment of the indoor module differs.

SCOP of up to
4.76¹kWh of heat per season for every kWh of electricity
Energy class up to
A+++¹at 35 °C flow temperature
Efficient operation down to
−25 °Coutside temperature
Flow temperature up to
65 °Cheating water temperature
Quiet operation, from
46 dB(A)²sound power level

¹ Best values in the range at 35 °C flow: SCOP 4.76 (AFM 16) and class A+++ (AFM 14–20), according to EN 14511, average climate. ² Sound power level in normal mode, AFM 9, according to EN 12102.

Technology

  • Copeland Scroll inverter compressor with wide power modulation
  • Eco-friendly refrigerant R452B (GWP 676)
  • High weather resistance thanks to the powder-coated aluminium housing

Control and connectivity

  • 7″ colour touchscreen display
  • Easy control via app, web application and smart home
  • Hybrid function for operation with a biomass boiler

Installation and use

  • Heating and cooling as standard
  • Simple and fast installation
  • The refrigeration circuit stays in the outdoor unit (monoblock)

Eight models, from 5 to 20 kW.

The same indoor module, combined with three outdoor unit sizes. Select a model to see its key data. We determine the output your building needs free of charge during the technical consultation.

Airflow-M COMFORT II with the 9–12 kW outdoor unit

Outdoor unit 9–12 kW1390 × 860 × 590 mm

Choose the model
5–7 kW
9–12 kW
14–20 kW
Heating capacity at A-7/W35*
6.62 kW
Modulation range
2–9 kW
SCOP at 35 / 55 °C*
4.21 / 3.34
Energy class at 35 / 55 °C
A++ / A++
Sound pressure at 5 m / 8 m***
24 / 20 dB(A)
Supply voltage
230 V / 50 Hz
DHW tank
250 l
All technical data, for every model

Technical data Airflow-M COMFORT II

Models 5–20 kW

Technical data Airflow-M COMFORT II
Unit 5–7 kWUnit 9–12 kWUnit 14–20 kW
Parameter
Performance
Modulation range (kW)
2–52–72–93–124–145–165–185–20
Heating capacity at A-7/W35 (kW)*
4.985.426.627.899.5712.0513.0113.78
Heating capacity at A-7/W55 (kW)*
4.775.186.457.799.3311.9512.8713.65
SCOP at 35 / 55 °C*
4.09 / 3.254.12 / 3.234.21 / 3.344.20 / 3.544.73 / 3.384.76 / 3.414.71 / 3.354.69 / 3.23
ETAs at 35 / 55 °C (%)*
160.5 / 127.1161.8 / 126.0165.5 / 130.6165.1 / 138.7186.1 / 132.2187.2 / 133.5185.2 / 131.0184.4 / 126.3
Energy class at 35 / 55 °C
A++ / A++A++ / A++A++ / A++A++ / A++A+++ / A++A+++ / A++A+++ / A++A+++ / A++
Sound
Sound power level normal / night (dB(A))**
54 / 5155 / 5246 / 4348 / 4550 / 4752 / 4953 / 5054 / 51
Sound pressure at 5 m / 8 m (dB(A))***
32 / 2833 / 2924 / 2026 / 2228 / 2430 / 2631 / 2732 / 28
Electrical supply
Supply voltage (V / Hz)
230 / 50230 / 50230 / 50400 / 50400 / 50400 / 50400 / 50400 / 50
Connection current (A)
1515153 × 123 × 123 × 123 × 123 × 12
Max electrical input (kW)
2.532.823.383.895.495.825.826.30
Dimensions and weight
Outdoor module dimensions (W × H × D) (mm)
1150 × 860 × 5151150 × 860 × 5151390 × 860 × 5901390 × 860 × 5901350 × 1505 × 5851350 × 1505 × 5851350 × 1505 × 5851350 × 1505 × 585
Indoor module dimensions (W × H × D) (mm)
695 × 1535 × 900695 × 1535 × 900695 × 1535 × 900695 × 1535 × 900695 × 1770 × 900695 × 1770 × 900695 × 1770 × 900695 × 1770 × 900
Weight outdoor / indoor module (kg)
129 / 205129 / 205148 / 205148 / 205210 / 265212 / 265212 / 265212 / 265
DHW tank (l)
250250250250310310310310

* according to EN 14511 (average climate); ** according to EN 12102; *** free-field installation

Swipe for all models

The outdoor unit and the indoor module

Each of the four indoor modules pairs with one of the three outdoor unit sizes, from 5 to 20 kW.

Airflow-M COMFORT II outdoor module

The monoblock system consists of two modules, one outdoor and one indoor, in the 5–20 kW range. The outdoor unit contains the entire refrigeration circuit: evaporator, compressor, condenser and expansion valve. The 3D model can be used to check the placement, including in augmented reality (AR).

Open 3D model in a new window
Airflow-M COMFORT II indoor module

Airflow-M COMFORT II indoor module

The entire heating and cooling installation is controlled via this unit's 7″ touch display. In addition to the STYLE equipment, the COMFORT II hydraulic module includes an integrated 250 / 310 l DHW tank, a storage protection anode, one direct and one mixed heating circuit.

Images of Airflow-M in the home and in the plant room

Airflow-M variant comparison

What comes integrated in each indoor module. The outdoor unit is the same.

Airflow-M variant comparison
FeatureAirflow-MBASICAirflow-MSTYLEAirflow-MCOMFORTThis pageAirflow-MCOMFORT II
Control of the full heating systemYesYesYesYes
Flow sensor includedYesYesYesYes
High-efficiency variable pumpYesYesYesYes
Magnetic dirt separator integratedNoYesYesYes
Electric heater integratedNoYesYesYes
Safety group integratedNoYesYesYes
Domestic hot water tank integratedNoNoYesYes
3-way valve integratedNoNoYesYes
Top hydraulic connectionsNoNoYesYes
Bottom hydraulic connectionsNoYesNoNo
1 direct heating circuitNoNoYesYes
1 mixed heating circuitNoNoNoYes

We determine the right variant and output for your building.

The heated floor area, how well it is insulated and which fuel you have to hand. The final quote follows the technical assessment.

or message us on WhatsApp
  • Free technical consultation
  • Authorised Hargassner dealer
  • Delivery and installation across Romania