Answer a few questions about the building and see the required output, the suitable systems and the estimated yearly heating cost. It takes about two minutes.

Step 1 of 9

What type of building do you want to heat?

How we calculate

Required output
The heated area multiplied by the specific heat load: 40–55 W/m² for new builds, 70–90 W/m² for renovated buildings and 100–130 W/m² for old, uninsulated buildings. Hotels and guesthouses add 0.5 kW per guest for hot water.
Yearly heat demand
The output multiplied by the full-load hours: 2,000 hours a year for homes, 1,200–1,400 hours for commercial buildings, depending on use. Hot water for guests is calculated separately, from 30–40 litres per person per day.
Yearly cost
The yearly demand divided by the efficiency and multiplied by the energy price, at indicative values from October 2026: wood chips 0.15 RON/kWh, pellets 0.32 RON/kWh, logs 0.25 RON/kWh, electricity 1.30 RON/kWh; gas 0.31 RON/kWh for households and 0.44 RON/kWh for companies, used only for the cost of your current heating. Prices include VAT. Efficiency 90% for pellet and wood chip boilers, 85% for log boilers; the heat pump with a seasonal performance factor of 3.5. Energy cost only, without investment and maintenance; for logs, the work of preparing the wood and loading the boiler is not included.
Buffer tank
For biomass boilers we recommend 50 litres per kW of output, at least 30 litres per kW.