Industrial wood chip boiler
Industrial cascades up to 10 MW
Magno boilers connected in cascade. One boiler can be shut down for maintenance without stopping the installation.
- output per boiler
- 280–2,500 kW
- base models
- 20
- fuel
Wood chips

Cascade control for industrial boilers
Magno boilers combined to suit the consumption profile
The Magno range for industrial applications can be configured in cascade for total outputs of up to 10 MW. The load is distributed automatically between the boilers, and the installation can be extended later as consumption grows.
The combination of Magno-UF, Magno-VR and Magno-SR
Power installed in cascade up to 10 MW
Modular operation with centralised control
Increased redundancy for continuous operation
Automatic load distribution between the boilers
Features and equipment
The points below are taken from the Hargassner documentation.
- For industrial applications with high heat consumption
- Continued operation during servicing
- Cascade control configured according to the needs of the project
- The installed output can be extended later
- Start-up and shutdown controlled by a central controller
- Sizing based on the consumption profile
How a cascade is configured.
The number of boilers, the load distribution and operation during servicing.
- 01
Dimensioning according to the consumption profile
- 02
Combine Magno-UF, Magno-VR and Magno-SR modules
- 03
Centralised start/stop control
- 04
Automatic distribution of the load between modules
- 05
Later expansion depending on the increase in consumption
- 06
Redundancy for maintenance without complete shutdown of the system

Choose the base boilers.
20 base models from 3 ranges, combinable in cascade. We set the configuration from a heat-load calculation.
Magno-UF 300-550 kWMagno-UF 300
280kW
rated output
Adjusts its output between 90 and 280 kW according to the heat demand.
- Efficiency (NCV)
- 94.0%
- Seasonal efficiency
- not available
- Dimensions (W × H × D)
- 1260 × 2300 × 3350mm
- Weight
- 4250kg
- Floor space
- 3.67m²
- Flue pipe
- 200mm
Technical data for every model.
Figures from the Hargassner datasheets for the Industrial cascades up to 10 MW range. Pick a column to see that model in detail.
| Magno-UF 300-550 kW | Magno-VR 300-600 kW | Magno-SR 800-2500 kW | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | ||||||||||||||||||||
| Rated output · kW | 280 | 300 | 501 | 550 | 300 | 350 | 399 | 450 | 499 | 550 | 600 | 850 | 995 | 900 | 999 | 1200 | 1400 | 2000 | 2250 | 2500 |
| Fuel heat input · kW | 297.9 | 319.8 | 533 | 587.6 | 318.1 | 369.2 | not available | not available | not available | not available | not available | 888.2 | 1041.9 | 942.4 | 1046.1 | 1260.5 | 1497.3 | 2128.3 | 2406.4 | 2663.1 |
| Minimum output · kW | 90 | 105 | 150 | 165 | 90 | 105 | 120 | 135 | 150 | 165 | 180 | 240 | 299 | 300 | 300 | 360 | 420 | 600 | 675 | 750 |
| Efficiency (NCV) at rated output · % | 94.0 | 93.8 | 94 | 93.6 | 94.3 | 94.8 | not available | not available | not available | not available | not available | 95.7 | 95.5 | 95.5 | 95.5 | 95.2 | 93.5 | 93.5 | 93.5 | 93.5 |
| Efficiency (NCV) at 30 % load · % | not available | not available | not available | not available | 92.8 | 92.5 | not available | not available | not available | not available | not available | not available | not available | not available | not available | not available | not available | not available | not available | not available |
| Seasonal space heating efficiency (ηs) · % | not available | not available | not available | not available | 79 | 80 | not available | not available | not available | not available | not available | 81 | 81 | not available | not available | 80 | not available | not available | not available | not available |
| Boiler temperature range · °C | 95 | 95 | 95 | 95 | 70-95 (110) | not available | 70-95 (110) | 70-95 (110) | 70-95 (110) | 70-95 (110) | 70-95 (110) | not available | not available | not available | not available | not available | not available | not available | not available | not available |
| Dimensions (W × H × D) · mm | 1260 × 2300 × 3350 | 1260 × 2300 × 3350 | 1460 × 2510 × 3875 | 1460 × 2510 × 3875 | 1260 × 2650 × 3350 | 1260 × 2650 × 3350 | 1450 × 2870 × 3925 | 1450 × 2870 × 3925 | 1450 × 2870 × 3925 | 1450 × 2870 × 3925 | 1450 × 2870 × 3925 | 1750 × 3700 × 5000 | 1750 × 3700 × 5000 | 1950 × 3980 × 5070 | 1950 × 3980 × 5070 | 1750 × 3700 × 5000 | 1950 × 3980 × 5070 | 1950 × 3980 × 6700 | 1950 × 3980 × 6700 | 1950 × 3980 × 6700 |
| Weight · kg | 4250 | 5200 | 6830 | 6830 | 5630 | 5630 | 7900 | 7900 | 7900 | 7900 | 7900 | 18000 | 18000 | 21400 | 21400 | 18000 | 21400 | 28500 | 28500 | 28500 |
| Floor space required · m² | 3.67 | 4.22 | 5.66 | 5.66 | 11.36 | 11.36 | 9.23 | 9.23 | 9.23 | 9.23 | 9.23 | 8.75 | 8.75 | 9.88 | 9.88 | 8.75 | 9.88 | 13.07 | 13.07 | 13.07 |
| Flue pipe diameter · mm | 200 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 350 | 350 | 400 | 400 | 400 | 400 | 400 | 400 | 500 | 500 | 500 |
| Ash box volume · l | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 300-800 | 300-800 | 300-800 | 300-800 | 300-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 | 240-800 |
| Water content · l | 830 | 1100 | 1550 | 1550 | 875 | 875 | 1500 | 1550 | 1500 | 1550 | 1550 | 2800 | 2800 | 3500 | 3500 | 2800 | 3500 | 5100 | 5100 | 5100 |
| Flow / return connection | 80/80 PN16* | 80/80 PN16* | 100/100 PN16* | 100/100 PN16* | 80/80 PN16* | 80/80 PN16* | 100/100 PN16* | 100/100 PN16* | 100/100 PN16* | 100/100 PN16* | 100/100 PN16* | 125/125 PN16* | 125/125 PN16* | 125/125 PN16* | 125/125 PN16* | 125/125 PN16* | 125/125 PN16* | 200/200 PN16* | 200/200 PN16* | 200/200 PN16* |
Values marked * refer to the notes in the Hargassner datasheet.
“–” = value not available for that model.
Swipe for all models
Recommended accessories
For fuel feeding, controls, storage and hot water, all compatible with Industrial cascades up to 10 MW.
AccessoriesOekoRonaFine dust filter for boilers from 250 kW.Details
AccessoriesAsh removal systemsFor wood chip and pellet boilers.Details
Filling systemsDriveable bunker filling lidFor flexible placement of the filling system.Details
Filling systemsInside ejectorMake maximum use of the volume of the storage room.Details
Filling systemsOutside ejectorFor filling through windows or wall openings.Details
Filling systemsHorizontal distribution augerFor filling hard-to-reach storage spaces.Details
Filling systemsFilling system with variable inclinationOptimum use of the storage room or the boiler room.Details
Filling systemsFilling auger with variable inclinationConvenient and automatic filling of hard-to-reach storage spaces.Details
Projects completed by Perfect Energy.
Hotels, guesthouses, villas and a bakery plant. Each project is presented with photos and the technical data of the system.
- projects completed
- 50+
- projects completed
- installed capacity
- 7,000+ kW
- installed capacity
All wood chip ranges
Request a quote for Industrial cascades up to 10 MW.
Send us the building data: its use, the floor area and the available fuel. An engineer recommends the model; the final quote is issued after the technical assessment.
- Free technical consultation
- Authorised Hargassner dealer
- Delivery and installation across Romania