Pellet boiler
Eco-PK 70-120 kW
Step grate and firebed control with a lambda sensor. Energy class up to A++.
- rated output
- 70–120 kW
- models
- 5
- fuel
Pellets

Automatic pellet heating
Eco-PK systems are designed for high thermal requirements. The model up to 120 kW is the entry class in the high temperature Eco range, suitable for residential complexes, restaurants and public buildings.
The Eco-PK 70-120 kW draws pellets into the day hopper by suction, even while it is running. As an option, the ash can be removed automatically into a 300 l container. The cross-section diagram and the 3D model show the main components.
Fully automated
Step grate system
Eco mode to reduce costs
Firebed level control with lambda sensor
Very low micro-dust levels
Features and equipment
The points below are taken from the Hargassner documentation.
- Energy saving and low costs
- Efficiency (NCV) of up to 94.6% at rated output
- Combustion chamber fully lined with refractory material
- Lambda sensor with fuel quality detection
- Energy-saving ignition: 300 W
- Standard flue gas recirculation
- Contactless ember bed monitoring with sensors
- Flame temperature monitoring
- Double rotary valve
- Suction of pellets during operation
- Return temperature boost can be integrated (optional)
- Automatic ash discharge (optional with 300-litre container)
- Modern touch display control
- Remote control via app
- 5-year warranty as per the Hargassner warranty certificate
- Energy class up to A++
- Particle filter (optional)
Choose the right output.
5 models in the Eco-PK 70-120 kW range. We size the right output from a heat-load calculation; technical advice is free.
Eco-PK 70-120 kWEco-PK 70
70kW
rated output
Adjusts its output between 21 and 70 kW according to the heat demand.
- Efficiency (NCV)
- 94.6%
- Seasonal efficiency
- 85* / 83*%
- Energy class
- A++
- Dimensions (W × H × D)
- 745 × 1610 × 1560mm
- Weight
- 965kg
- Floor space
- 1.15m²
Technical data for every model.
Figures from the Hargassner datasheets for the Eco-PK 70-120 kW range. Pick a column to see that model in detail.
| Model | |||||
|---|---|---|---|---|---|
| Rated output · kW | 70 | 90 | 99 | 108 | 120 |
| Fuel heat input · kW | 74 | 95.6 | 105.5 | 115.4 | 128.6 |
| Minimum output · kW | 21 | 27 | 29.7 | 32.4 | 36 |
| Efficiency (NCV) at rated output · % | 94.6 | 94.1 | 93.8 | 93.6 | 93.3 |
| Efficiency (NCV) at 30 % load · % | 95.2 | 95.3 | 95.3 | 95.4 | 95.4 |
| Efficiency (GCV) at rated output · % | 87.6 | 87.1 | 86.9 | 86.7 | 86.4 |
| Efficiency (GCV) at 30 % load · % | 88.3 | 88.3 | 88.3 | 88.3 | 88.3 |
| Seasonal space heating efficiency (ηs) · % | 85* / 83* | 85* / 83* | 85* / 84* | 85* / 84* | 85* / 84* |
| Boiler temperature range · °C | 69 - 90 (opt. 95 C) | 69 - 90 (opt. 95 C) | 69 - 90 (opt. 95 C) | 69 - 90 (opt. 95 C) | 69 - 90 (opt. 95 C) |
| Dimensions (W × H × D) · mm | 745 × 1610 × 1560 | 745 × 1610 × 1560 | 745 × 1610 × 1560 | 745 × 1610 × 1560 | 745 × 1610 × 1560 |
| Weight · kg | 965 | 965 | 990 | 990 | 990 |
| Floor space required · m² | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 |
| Flue pipe diameter · mm | 180 | 180 | 180 | 180 | 180 |
| Ash box volume · l | 30 / 60** | 30 / 60** | 30 / 60** | 30 / 60** | 30 / 60** |
| Water content · l | 180 | 180 | 180 | 180 | 180 |
| Flow / return connection · in | 6/4 | 6/4 | 6/4 | 6/4 | 6/4 |
| Energy efficiency class | A++ | not available | not available | not available | not available |
Values marked * refer to the notes in the Hargassner datasheet.
“–” = value not available for that model.
Swipe for all models
Boiler components.
Cross-section of the Eco-PK 70-120 kW. The numbers in the drawing correspond to the components in the list. The image can be enlarged.
Key components
- 1Step grate system
- 2Firebed level control
- 3Turbulators with automatic boiler cleaning system (also in the 1st pass)
- 4Ash box 30 l; optional: ash suction system for very long maintenance intervals
- 5Automatic ignition with 300 W
- 6Exhaust fan (EC motor) with negative pressure monitoring
- 7Recirculation
- 8Integrated return temperature protection (optional)
- 9Ash removal system for fine ash and grate ash
- 10Heat exchanger: no thermal safety circuit required
- 11Negative pressure monitoring
- 12Combustion chamber fully lined with refractory material
- 13Flame concentration plate made of high quality refractory material
- 14Daily hopper for pellets
- 15Level indicator
- 16Feeding auger
- 17Double dosing rotary valve
- 18Pellet suction turbine
- 19Acoustic insulation
- 20Lambda sensor
- 21Flame temperature monitoring
Eco-PK 70-120 kW 3D model
The model can be rotated and enlarged to show the construction details. It is useful when planning the plant room.
The viewer loads from the external provider rooom.
Recommended accessories
For fuel feeding, controls, storage and hot water, all compatible with Eco-PK 70-120 kW.
Storage systemsBag Silo for outdoor mountingGarden shed used as a pellet store.Details
Storage systemsBag SiloPellet storage system for the storage room.Details
Storage systemsFuel extraction augerCombination of suction system and extraction auger for pellet boilers.Details
Storage systemsPoint Suction RAPSPellet storage system for any room shape.Details
Heating modulesHeating moduleCombined boiler room and fuel store.Details
Heating modulesPower-BoxEfficient drying and heating.Details
AccessorieseCleanerFine dust filter for the high output range.Details
Water storage tanksHygienic stratified tankHygienic tank for hot water.Details
Projects completed by Perfect Energy.
Hotels, guesthouses, villas and a bakery plant. Each project is presented with photos and the technical data of the system.
- projects completed
- 50+
- projects completed
- installed capacity
- 7,000+ kW
- installed capacity
All pellet ranges
Request a quote for Eco-PK 70-120 kW.
Send us the building data: its use, the floor area and the available fuel. An engineer recommends the model; the final quote is issued after the technical assessment.
- Free technical consultation
- Authorised Hargassner dealer
- Delivery and installation across Romania